Command Reference
R&S
®
CMW-B400B/-B405A
83
User Manual 1176.8116.02 ─ 04
SOURce:AUDio:GEN<i>:ANALog:STYPe
<SignalType>
SOURce:AUDio:GEN<i>:DIGital:STYPe
<SignalType>
Selects the type of the generated audio signal.
Parameters:
<SignalType>
SINGletone | MULTitone | FFTNoise
*RST:
SING
Example:
See
Firmware/Software:
V3.2.10
Manual operation:
See
SOURce:AUDio:GEN<i>:ANALog:ACOupling
<Analyzer>
SOURce:AUDio:GEN<i>:DIGital:ACOupling
<Analyzer>
Selects the audio measurement to which the audio generator is coupled.
Parameters:
<Analyzer>
OFF | ANAL | DIG
OFF:
no coupling
ANAL:
analog measurement
DIG:
digital measurement
*RST:
OFF
Example:
See
Firmware/Software:
V3.2.10
Manual operation:
See
6.4.3 Single Tone Generator Settings
The following commands configure single tone signals.
SOURce:AUDio:GEN<i>:ANALog:SINGletone:FREQuency
..................................................83
SOURce:AUDio:GEN<i>:DIGital:SINGletone:FREQuency
....................................................83
SOURce:AUDio:GEN<i>:ANALog:SINGletone:LEVel
...........................................................84
SOURce:AUDio:GEN<i>:DIGital:SINGletone:LEVel
.............................................................84
SOURce:AUDio:GEN<i>:ANALog:SINGletone:FREQuency
<Frequency>
SOURce:AUDio:GEN<i>:DIGital:SINGletone:FREQuency
<Frequency>
Specifies the frequency of the single tone to be generated.
Parameters:
<Frequency>
Range:
0 Hz to 21E+3 Hz
*RST:
1000 Hz
Default unit: Hz
Example:
See
Audio Generators