R&S FSH-K1
Command Description
1157.3564.12 69
E-8
PCCPCHSYMEVM (P-CCPCH Symbol EVM)
This command retrieves the P-CCPCH Symbol EVM measurement result for WCDMA measurements.
Unit is % rms.
Example:
get<cr>
0<cr>
pccpchsymevm<cr>
‘get P-CCPCH Symbol EVM
0<cr>
‘responds
parameter
ok
63.9<cr>
‘P-CCPCH Symbol EVM is 63.9 % rms
PSCHPWR (P-SCH Power)
This command retrieves the P-SCH Power measurement result for WCDMA measurements. Unit is
dBm.
Example:
get<cr>
0<cr>
pschpwr<cr>
‘get
P-SCH
Power
0<cr>
‘responds
parameter
ok
13<cr>
‘P-SCH Power is 13 dBm
PSCRCD (Primary Scramble Code)
This command defines the primary part of the scrambling code. The scrambling code is divided into 2
parts, a primary and a secondary part.
Valid input for primary scrambling code varies from 0 to 1535 (0x00 – 0x600-1). From the primary and
secondary scrambling codes the common scrambling code can be calculated as follows.
ondary
primary
BS
Scr
Scr
Scr
sec
16
+
=
Example:
set<cr>
0<cr>
pscrcd,123<cr>
‘set prim. scramb. code to 123
0<cr>
‘responds parameter ok
If an auto scrambling detection multiple has been performed successfully the get command allows an
option parameter.
Optional Value
Scrambling Code id
1…6 id
1…6
Example:
get<cr>
0<cr>
pscrcd,4<cr>
‘get prim scrambling code of id 4
0<cr>
‘responds
parameter
ok
1<cr>
‘prim scambling code number is 1