R&S FSH-K1
Command Description
1157.3564.12 37
E-8
MARKPK (Marker Peak)
This command sets the current or corresponding marker to the peak (highest signal).
Optional Value
Marker
1…6 Marker
1…6
Example:
cmd<cr>
0<cr>
markpk<cr>
‘set marker to peak
0<cr>
‘responds parameter ok
Example 2:
cmd<cr>
0<cr>
markpk,4<cr>
‘set multi marker 4 to peak
0<cr>
‘responds parameter ok
MARKNXTPK (Marker Next Peak)
This command sets the current or corresponding marker to the next peak.
Optional Value
Marker
1…6 Marker
1…6
Example:
cmd<cr>
0<cr>
marknxtpk<cr>
‘set marker to next peak
0<cr>
‘responds parameter ok
MARKMIN (Marker Minimum)
This command sets the current or corresponding marker to the minimum (lowest signal).
Optional Value
Marker
1…6 Marker
1…6
Example:
cmd<cr>
0<cr>
markmin<cr>
‘set marker to minimum
0<cr>
‘responds parameter ok
MARKTOCENT (Marker Frequency To Center Frequency)
This command sets the current or corresponding marker as center frequency.
Optional Value
Marker
1…6 Marker
1…6
Example:
cmd<cr>
0<cr>
marktocent<cr>
‘set marker frequency to center frequency
0<cr>
‘responds parameter ok