Command Description
R&S FSH-K1
1157.3564.12 36
E-8
DELTAALLON (All Deltamarker On)
This command turns all deltamarker on / off. This command is available in multi marker mode only.
Value
All Deltamarker
0
OFF
1
ON
Example:
set<cr>
0<cr>
deltaallon,1<cr>
‘turns
all
deltamarker
on
0<cr>
‘responds parameter ok
MARKALL? (Multimarker)
This command queries the current list of multimarkers. Each multimarker returns three numbers:
multimarker number, x-axis value, y-axis value. This GET command is available in multi marker mode
only.
The unit of the second number in the GET command response depends on the unit of the x-axis which
can be Hz, seconds or meter/feet depending of the measurement mode. The unit of the third value in
the GET command response depends on the current unit of the y-axis.
Example:
get<cr>
0<cr>
markall?<cr>
‘query multi marker list (e.g. 2 multimarkers)
0<cr>
‘responds parameter ok
1,103.4e6,-45.66,2,110.8e6,-23.67<cr>
DELTAALL? (Multi Deltamarker)
This command queries the current list of multi deltamarker values. Each delta multimarker returns three
numbers: delta multimarker number, x-axis value, y-axis value. This GET command is available in multi
marker mode only.
The unit of the second number in the GET command response depends on the unit of the x-axis which
can be Hz, seconds or meter/feet depending of the measurement mode. The unit of the third value in
the GET command response depends on the current unit of the y-axis.
Example:
get<cr>
0<cr>
deltaall?<cr>
‘query delta marker list (e.g. 3 delta multimarker)
0<cr>
‘responds parameter ok
1,-100.0e3,-6.02,2,100.5e3,-3.67,3,300.4e6,-12.5<cr>