RCVDL56DPFL/SP, RCV56DPFL/SP, and RCV336DPFL/SP Designer’s Guide
1119
13-9
13.2.5 “Room Monitor” Mode
To operate in “room monitor” mode:
1. Set CONF = ACh.
2. Set RXV = 1.
3. Select the output to TXA1/TXA2 to come from SR4OB (3E0h).
4. Setup the voice IA mic level to 20 dB gain (14).
5. Disable the output to SPKV (VSpkDis), SPKM (MSpkDis), and TELOUT (VLinDis).
6. Set
VAGC.
7. Select the “record” path to come from the Voice IA (43Eh).
8. Set
NEWC.
In this mode, the tone detectors (including the DTMF receiver) are operational.
13.2.6 Voice Idle Mode
It is recommended that RXV be set when operating in voice idle mode from configuration ACh. This allows the transmitter to
be used for tone generation (like dialing).
13.2.7 Business Audio (Sampling Frequency = 11025 Hz)
To enable business audio, set bit 43Eh:7. This bit takes effect at NEWC when CONF = ACh. (RXV and/or TXV must also be
set.)
13.3 VOICE AGC
See Section 11.3.
13.4 SPEAKERPHONE CONVERSTATION RECORD
When in speakerphone mode, the conversation may be recorded by enabling variable gains on both the transmit and receive
paths and reading samples from RBUFFER just as in voice pass through mode with the exception that RXV must be set to
0. The gain locations are AF0h for the transmitter (local speaker) and AF1h for the receiver (incoming voice). Both of these
locations default to 0000h. The higher the value, the higher the gain.
Record Procedure
1. Connect in speakerphone mode.
2. Ensure RXV = 0.
3. Write the desired gain values in AF0h and AF1h; a value of 2000h is generally suitable.
4. Read in samples through RBUFFER as per voice pass through record procedure. (See Section 11.)