Programming and Parameters
3-7
Display Group
(continued)
d018 [Elapsed Run Time]
Accumulated time drive is outputting power. Time is displayed in 10 hour increments.
Values
Default
Read Only
Min/Max:
0/9999 Hrs
Display:
1 = 10 Hrs
d019 [Testpoint Data]
The present value of the function selected in A102
Values
Default
Read Only
Min/Max:
0/FFFF
Display:
1 Hex
d020 [0-10V Analog Input]
Related Parameter(s):
The present value of the voltage at I/O Terminal 13 (100.0% = 10 volts).
Values
Default
Read Only
Min/Max:
0.0/100.0%
Display:
0.1%
d021 [4-20mA Analog Input]
Related Parameter(s):
The present value of the current at I/O Terminal 15 (0.0% = 4mA, 100.0% = 20mA).
Values
Default
Read Only
Min/Max:
0.0/100.0%
Display:
0.1%
userman.book Page 7 Friday, June 21, 2002 2:48 PM
Summary of Contents for Allen-Bradley PowerFlex 4
Page 4: ...soc 2 userman book Page 2 Friday June 21 2002 2 48 PM ...
Page 6: ...ii userman book Page ii Friday June 21 2002 2 48 PM ...
Page 32: ...1 22 Installation Wiring Notes userman book Page 22 Friday June 21 2002 2 48 PM ...
Page 70: ...4 8 Troubleshooting Notes userman book Page 8 Friday June 21 2002 2 48 PM ...
Page 74: ...A 4 Supplemental Drive Information Notes userman book Page 4 Friday June 21 2002 2 48 PM ...
Page 82: ...B 8 Accessories and Dimensions Notes userman book Page 8 Friday June 21 2002 2 48 PM ...
Page 88: ...C 6 RS485 DSI Protocol Notes userman book Page 6 Friday June 21 2002 2 48 PM ...
Page 92: ...Index 4 Notes userman book Page 4 Friday June 21 2002 2 48 PM ...
Page 93: ...userman book Page 1 Friday June 21 2002 2 48 PM ...