Troubleshooting
4-7
Motor operation is unstable.
Drive will not reverse motor direction.
Cause(s)
Indication
Corrective Action
Motor data was incorrectly
entered.
None
1. Correctly enter motor nameplate
data into
,
2. Enable A097
3. Use A084
boost level.
Cause(s)
Indication
Corrective Action
Digital input is not selected for
reversing control.
None
Check [Digital Inx Sel]
. Choose correct input
and program for reversing mode.
Digital input is incorrectly
wired.
None
Check input wiring.
Motor wiring is improperly
phased for reverse.
None
Switch two motor leads.
Reverse is disabled.
None
Check A095
.
userman.book Page 7 Friday, June 21, 2002 2:48 PM