Programming and Parameters
3-19
Advanced Program Group
(continued)
A084 [Start Boost]
Sets the boost voltage (% of P031
) and redefines the Volts per Hz curve.
(1)
(1)
Drive may add additional voltage unless Option 5 is selected.
Options
1
“30.0”
Variable Torque
2
“35.0”
3
“40.0”
4
“45.0”
5
“0.0 no IR Comp”
Constant Torque
6
“0.0”
7
“2.5”
[Default for 3.7kW
(5HP) Drives]
8
“5.0” (Default)
9
“7.5”
10
“10.0”
11
“12.5”
12
“15.0”
13
“17.5”
14
“20.0”
% [Motor NP Hertz]
% [Motor NP Volts]
100
50
1/2 [Motor NP Volts]
1/2
[Motor NP Hertz]
4
3
2
1
0
50
100
Settings
5-14
A088 [Maximum Voltage]
Sets the highest voltage the drive will output.
Values
Default
Drive Rated Volts
Min/Max:
20/Drive Rated Volts
Display:
1 VAC
userman.book Page 19 Friday, June 21, 2002 2:48 PM
Summary of Contents for Allen-Bradley PowerFlex 4
Page 4: ...soc 2 userman book Page 2 Friday June 21 2002 2 48 PM ...
Page 6: ...ii userman book Page ii Friday June 21 2002 2 48 PM ...
Page 32: ...1 22 Installation Wiring Notes userman book Page 22 Friday June 21 2002 2 48 PM ...
Page 70: ...4 8 Troubleshooting Notes userman book Page 8 Friday June 21 2002 2 48 PM ...
Page 74: ...A 4 Supplemental Drive Information Notes userman book Page 4 Friday June 21 2002 2 48 PM ...
Page 82: ...B 8 Accessories and Dimensions Notes userman book Page 8 Friday June 21 2002 2 48 PM ...
Page 88: ...C 6 RS485 DSI Protocol Notes userman book Page 6 Friday June 21 2002 2 48 PM ...
Page 92: ...Index 4 Notes userman book Page 4 Friday June 21 2002 2 48 PM ...