86
Rockwell Automation Publication 20P-TG004C-EN-P - September 2021
Chapter 3
Access Procedures
AC Current Transducers
Removal and Installation
Remove the AC Current Transducers
1.
Read the General Safety Precautions on page
2.
Remove power from the drive. See Remove Power from the Drive on page
3.
Remove the top terminal cover from the drive. See Remove the Protective
Covers on page
4.
Loosen, but do not remove, the six hexalobular screws that secure the top
airflow plate to the drive, then slide the plate forward to lift it off the
screws.
Note: The airflow plate cannot be removed from the drive unless the AC
input wiring and busbar extensions (if installed) are removed.
5.
Open the control panel. See Open the Control Panel on page
Tightening torque:
1.5 N
•
m (13 lb
•
in)
T15
4
4
Top View of Drive
Fan loss detection board
IMPORTANT
Mark all connections and wires before removal to avoid incorrect