![Rockwell Automation Allen-Bradley PowerFlex 20P Manual Download Page 47](http://html.mh-extra.com/html/rockwell-automation/allen-bradley-powerflex-20p/allen-bradley-powerflex-20p_manual_1475484047.webp)
Rockwell Automation Publication 20P-TG004C-EN-P - September 2021
47
Access Procedures
Chapter 3
Protective Cover Removal
and Installation
Remove the Protective Covers
1.
Read the General Safety Precautions on page
.
2.
Remove power from the drive. See Remove Power from the Drive on page
.
3.
If necessary, disconnect the DPI cable from the HIM (if present).
4.
Loosen, but do not remove, the hexalobular screws that secure the cover to
the drive chassis, slide the cover up or down, and lift the cover off the drive.
IMPORTANT
The HIM is connected via a cable to the control board and therefore the
bottom control panel cover cannot pull free from the drive until the
cable is disconnected. The cover does, however, have notches on the
side in order that it can be hung on the screws without disconnecting
the HIM cable.
=
3
Tightening torque:
1.5 N
•
m (13 lb
•
in)
T15
4
Removing this cover provides access to the fan loss detection
board, fan motor and blower, and AC current transducers.
Top control panel
cover
Bottom control
panel cover
Top terminal cover
I/O and control
terminal cover
Bottom terminal
cover
Removing these covers provides access to the field board,
field SCR and dual diode modules, switching power supply
board, pulse transformer board, and control board.
Removing this cover provides access to the control power,
relay, thermistor/thermal switch, armature fuse signal, I/O,
digital encoder, DC analog tachometer, and resolver feedback
terminals.
Removing this cover provides access to the snubber
capacitors and snubber resistors.
4
4
4