![Rockwell Automation Allen-Bradley PowerFlex 20P Manual Download Page 103](http://html.mh-extra.com/html/rockwell-automation/allen-bradley-powerflex-20p/allen-bradley-powerflex-20p_manual_1475484103.webp)
Rockwell Automation Publication 20P-TG004C-EN-P - September 2021
103
Access Procedures
Chapter 3
2.
Remove power from the drive. See Remove Power from the Drive on page
.
3.
Open the control panel. See Open the Control Panel on page
4.
Disconnect the resistor wires from connector XR-6 on the overvoltage
clipping board. Note: On older boards, these connections are soldered
directly to the board. In this case, unsolder the connections.
IMPORTANT
Mark all connections and wires before removal to avoid incorrect
wiring during reassembly.
XCD
X1UVW1
XUVW
F31
F21
F11
XCD
X1UVW1
XUVW
F31
F21
F11
XR-5
XR-4
XR-3
XR-2
XR-1
C5gn
C4blu
C7gn
C7blu
XR-6
4
Newer overvoltage clipping board
Older overvoltage clipping board