76
Rockwell Automation Publication 20P-TG004C-EN-P - September 2021
Chapter 3
Access Procedures
7.
Remove the two hexalobular screws that secure the bottom of the fuse
holder to the control pan. Retain the screws for reuse.
8.
Place the tip of a flathead screwdriver in the slot of the two tabs at the base
of the fuse holder and pull down until the tabs pull out from the fuse
holder body. When then fuse holder is loose, remove it from the metal
support flange.
Install the Field Fuse Holder
Install the field fuse holder in the reverse order of removal.
Fan Starting Capacitor
Removal and Installation
Remove the Fan Starting Capacitor
Note:
A fan capacitor is only used on series A, frame D drives. See
for information on identifying series A drives.
1.
Read the General Safety Precautions on page
2.
Remove power from the drive. See Remove Power from the Drive on page
3.
Remove the top terminal cover from the drive. See Remove the Protective
Covers on page
8
7
IMPORTANT
Mark all connections and wires before removal to avoid incorrect
wiring during reassembly.