Placing and Configuring the Drive
2-21
Accessing Drive Data
Drive data is displayed as structures of multiple tags. The names and data
structures are based on the selected communication format. The
programming software automatically creates the necessary structures and
tags when you configure the drive module. Each tag name follows this
format:
ModuleName:Type.MemberName.SubMemberName.Bit
where:
Communication Formats on page 2-5
for sample tag names.
Monitoring Drive Data
The DriveLogix controller offers different levels at which you can monitor
the drive module. You can:
•
configure the drive module so that the controller faults if the drive loses
its connection to the controller.
•
use the programming software to display fault data
•
program logic to monitor fault data so you can take appropriate action
This address variable:
Is:
ModuleName
Identifies the module name entered during the drive module
configuration
Type
Type of data
I = input
O = output
MemberName
Specific data from the drive; depends on the selected communication
format.
For tags associated with pre-defined data links, this name will be the
same as the corresponding parameter name in the drive.
SubMemberName
Specific data related to a MemberName
Bit (optional)
Specific bit of a DINT data value
Summary of Contents for Allen-Bradley DriveLogix 5730
Page 6: ...4 ...
Page 10: ...p 4 Notes ...
Page 22: ...1 12 What is DriveLogix5730 Notes ...
Page 68: ...3 20 Placing and Configuring Local I O Notes ...
Page 134: ...6 36 Communicating with Devices on an EtherNet IP Link Notes ...
Page 182: ...9 10 Communicating with Devices on a DH485 Link Notes ...
Page 200: ...B 10 Access Procedures Notes ...
Page 205: ......
Page 206: ......
Page 207: ......