7-2
Communicating with Devices on an ControlNet Link
sure it’s properly installed in the DriveLogix controller. Refer to
the Communications Daughtercard on page B-9
You’ll need to configure the communication daughtercard slot number to 1
in the RSLogix 5000 programming software. The DriveLogix controller
uses slot 0 for the Communication Format with the local drive.
For more information about configuring a 1788-CNx communication
daughtercard, see:
Configuring the Communication Driver
Use RSLinx software to configure the ControlNet communication driver.
Select the appropriate communication driver for the communication
daughtercard in your workstation.
For this card:
See this document:
1788-CNC, -CNCR
1788-IN002
1788-CNF, -CNFR
1788-IN005
1.
In RSLinx software, select Configure Driver. Select the appropriate driver.
The installation instructions for the communications daughtercard should identify
which communication driver to install.
2.
Specify the appropriate settings. For example.
If you are using this device:
Specify this information:
1784-KTCx card
memory address, which must match the switch setting on the card
I/O base address, which must match the switch setting on the card
ControlNet node address
1784-PCC card
ControlNet node address (MAC ID)
1784-PCIC card
ControlNet node address (MAC ID)
Summary of Contents for Allen-Bradley DriveLogix 5730
Page 6: ...4 ...
Page 10: ...p 4 Notes ...
Page 22: ...1 12 What is DriveLogix5730 Notes ...
Page 68: ...3 20 Placing and Configuring Local I O Notes ...
Page 134: ...6 36 Communicating with Devices on an EtherNet IP Link Notes ...
Page 182: ...9 10 Communicating with Devices on a DH485 Link Notes ...
Page 200: ...B 10 Access Procedures Notes ...
Page 205: ......
Page 206: ......
Page 207: ......