You need RSLinx software version 2.41 or higher.
1
. Make sure the controller that uses the IP address is installed and running.
2
. Make a serial connection to the controller via the CH0 serial connector.
You might also need to use RSLinx software to create a DF1 driver for the workstation. See
3
. Start RSLinx. Open the RSWho window. Navigate in RSWho to the Ethernet network.
4
. Right-click on the Ethernet port (not the controller) and select Module Configuration
5
. Select the Port Configuration tab, choose Static Network Configuration type, and enter the IP address, network (subnet) mask, and
gateway address (if needed).
You must leave the Static radio button selected to permanently assign this configuration to the port. If you select Dynamic, the
controller clears its IP configuration and sends BOOTP requests on every power cycle and drive reset.