OPERATION: EXTRA FUNCTIONS
64
5.6
Electronic water level control
The purpose of the electronic water level control is to be able to continuously top up during spraying.
Principle of operation
There is a float in the water tank. This switch controls the solenoid valve in the filling line. When the water
level is too high, the solenoid valve closes. When the water level is too low, the solenoid valve opens. You
are therefore assured of water during spraying.
Filling the water tank
Stopping filling
5.7
Suction venturi
Purpose:
The suction venturi enables you to fill the water tank with surface
water.
Principle of operation:
The water in the water tank is pumped through the suction venturi. A vacuum forms in the suction venturi.
This vacuum draws in the surface water. All the water mixes and ends up in the water tank.
Preparation:
You should always check that there is still water in the water tank. If not, the suction venturi cannot
function.
1. Connect a filling hose to the coupling of the filling line on the machine.
2. Turn on the mains water supply tap.
3. Turn on the switch for the water level control.
The water tank is now filled with water.
1. Close the mains water supply tap.
2. Press the button of the solenoid valve. This releases the pressure from the
filling line.
3. Disconnect the filling hose from the coupling of the filling line.
Summary of Contents for CityJet
Page 1: ...CityJet user manual...
Page 4: ...4...
Page 8: ...INTRODUCTION 8...
Page 10: ...DESCRIPTION AND PRINCIPLE OF OPERATION 10 1 6 2 3 4 5 12 13 11 10 7 8 9 8...
Page 11: ...DESCRIPTION AND PRINCIPLE OF OPERATION 11 14 16 15 17...
Page 12: ...DESCRIPTION AND PRINCIPLE OF OPERATION 12 24 26 25 27 28 23 18 19 20 22 21 31 30 29 32...
Page 36: ...SAFETY 36...
Page 50: ...OPERATION STANDARD FUNCTIONS 50...
Page 70: ...OPERATION EXTRA FUNCTIONS 70...
Page 86: ...MALFUNCTIONS 86...
Page 90: ...90...
Page 91: ...ATTACHMENTS 91 9 Attachments...
Page 98: ...ATTACHMENTS 98...