MALFUNCTIONS
81
7.1.10 Troubleshooting
Below you will find a list of faults, their possible causes and the corresponding solution for each cause.
Fault
Cause
Solution
Engine will not start or stops
suddenly.
Fuel tank empty.
Refill the fuel tank.
Main or accessory fuse blown.
1.
Replace defective fuse.
2.
Restart engine.
3.
If the fuse blows again,
contact Rioned.
Battery voltage too low.
Charge the battery or replace the
battery
Air in fuel line.
Bleed air at engine.
Riomote control not switched on.
1.
Turn on the
Riomote control
.
2.
Repeat procedure from
section ‘
Preparation for use
’.
Riomote control Battery flat.
Charge battery or replace battery.
Water tank empty.
Fill water tank.
Water temperature too high.
Fill water tank or let water cool.
Hydraulic oil temperature too high.
Let oil cool.