MAIN COMPONENTS DISASSEMBLY
COMBUSTION FAN
1 -
Unplug the boiler.
2 -
Remove the front panel and the siphon.
3 -
Disconnect the electrical wiring.
4 -
Remove the fixing screws (4x).
GAS VALVES
1 -
Unplug the boiler.
2 -
Remove the front panel, the siphon and the PCB.
3 -
Remove the manifold (refer to the “Gas conversion and
pressure adjustment” paragraph).
4 -
Unplug the electrical wiring of the gas valves.
5 -
Remove the clip fastening the gas duct to the coupling in the
bottom part of the boiler.
6 -
Pull out the gas valves - see the drawing on the side - and
make sure not to damage the coupling o-ring.