7 | Malfunctions and faults
96 / 148
User and maintenance manual
Fault
Possible cause
Remedy
Person responsible*
Motor defective
Check motor by replacing it
OS
No ENPO start connec-
tion
Check ENPO cable connection
OS
Kart moves inadvertently Drive sensor incorrectly set Adjust drive sensor
OS
Ground conductor of con-
troller defective
Check ground conductors
OS
Pedal bent or incorrectly set Check pedal; replace, if necessary OS
* OP = operator's personnel, OS = operator's skilled worker, M = manufacturer
Tab. 23:
Fault list
7.2.2
Eliminating faults
NOTICE
Troubleshooting
If you have any queries, contact RiMO service department.
Faults must only be rectified by authorised skilled workers and other qualified person-
nel.
7.2.2.1
Control box
The control box contains the main cables for electrical components and provides mechanics with a well-
organised board for fault location and measurements. The control box also contains the main fuses.
Fig. 58:
Control box
1 Control box