7 | Malfunctions and faults
94 / 148
User and maintenance manual
a)
Take place on the driver seat.
b)
Check whether the
main switch is switched on.
c)
If necessary, switch on the
main switch.
d)
Turn the
drive switch.
e)
The green
drive switch indicator is lit.
The kart is switched on and ready for operation.
NOTICE
If you are unable to reset the emergency-stop function, leave the kart switched off. Do
not carry out any work on the kart. Contact RiMO service department for advice.
7.2
Faults and malfunction during operation
7.2.1
Fault list
NOTICE
Troubleshooting
All tasks described below must be performed by authorised technicians or skilled
workers. If you are unsure how to proceed, contact RiMO service department.
Fault
Possible cause
Remedy
Person responsible*
Kart cannot be started (no
power)
Fuse defective
Check fuse F1 (BMS)
OP
Cable disconnected/wire
break
Check all cables (+ and -) for
damage
OS
Kart not charged
Charging plug/socket
defective
Check charging plug, socket and
cable
OP
Main switch actuated
Check main switch
OP
Temperature outside
permissible range
(min./max.)
Check temperatures of BMS and
cells
OS
BMS fault
Check BMS
OS