Cleaning the flue blower casing
The flue blower should be cleaned at least 2 x a year or after approx. 700 kg
pellets.
The rear panel is to be removed for inspecting and cleaning the flue gas
fanCleaning the flame temperature sensor
To do this undo the four hexagon bolts that secure the flue gas fan motor in
place and carefully remove the flue gas fan motor from the housing.
Remove the fly ash from the blower and flue gas pipes with a vacuum cleaner.
Take care that seals are correct when closing
To clean the flue pipe connection disconnect the flue pipe from the flue gas fan
and vacuum the flue gas fan housing
Re-assembly the parts removed in reverse order.
Cleaning the flame temperature sensor
Remove the dust deposits from the sensor at regular intervals. Use a clean
cleaning cloth or newspaper.
Cleaning the pellet container
Do not refill the completely empty container immediately; remove the residues
(dust, chippings etc.) from the empty container. The unit must be disconnected
from the mains!
Checking door seal
The condition of the seals at doors and glass should be checked at least 1 x per
year. Repair or replace seals depending on condition.
Checking chimneay connection
Inspect and clean connection. Accumulated fly ash may impair the performance
of the stove and pose a safety risk.