23
EN
22
10. WARNING AND ERROR MESSAGES
During operation, unforeseen circumstances or intervention by the user may lead to malfunctions or interruptions of the control process. There is a differentiation
between warnings and error messages. Warnings are interruptions caused by the user; they can be eliminated by correct actions. Error messages are malfunctions
of components or discharges during operation. These must be acknowledged by the user so that operation can continue.
Note
If error messages recur directly, customer service is to be notified immediately. In the case of error messages that pose a safety risk, burnback and flue gas
flap is activated and the stove is automatically switched off.
Warnings
display
meaning
action to be taken
Please Close Doors
WARNING
PELLET HOPPER
LID AND
DOOR OPEN
Display for open combustion chamber door and
pellet container lid.
Close the combustion chamber door and the pellet
container lid.
WARNING
ROOMSENSOR
SIGNAL LOST
Manual Mode
There is no valid signal between the stove control
system and the room sensor.
Check if the sensor is plugged in correctly
ERROR
PLEASE PERFORM
SERVICE
Perform service (maintenance)
Perform service (see CLEANING AND MAIN-
TENANCE)