13. INSTRUCTIONS FOR COMMISSIONING PROTOCOL 

FOR PELLET AND COMBI STOVES

The commissioning protocol is to be treated as a documents and serves as 

the basis for the warranty and guarantee terms. It is to be completed entirely, 

in particular the stove data and addresses, the work to be performed is to be 

ticked off after completion. The signatories confirm with their signatures that all 

the items on the list have been concluded properly.

Note

Please return 1 completed protocol for putting into service to RIKA Innovative 

Ofentechnik GmbH, Müllerviertel 20, A-4563 Micheldorf.

Electrical periphery

It is important that the connection socket in the electrical periphery is earthed. 

The operability of any room thermostat present must be checked. The execution 

of commands is to be established by phoning in the case of a GSM modem.

Exhaust gas system

The exhaust line, stove and combustion air inlet are part of the combustion 

system as a whole; therefore the correct execution must also be checked. 

The plug connections should be tight in general since the system works 

with excess pressure. The exhaust tube has a diameter of 150 mm which is 

sufficient for short distances. In the case of several changes in direction, the 

resistance of the exhaust system can increase with the flue to such an extent 

that the combustion quality suffers and/or noises arise from the greater flow 

speed. Correct determination of the chimney draught can only be performed 

at nominal thermal output and serves to evaluate the chimney. If the draught is 

more than 15 Pa, then a draught limiter should be installed.

Stove functions

These are the basic stove functions that are to be checked and ticked off. The 

stove is ready for operation if these functions are ensured.

Operator instruction

This is one of the most important points in the putting into operation. It is very 

important that the operator understands the stove properly and is prepared to 

assume responsibility for the basic tasks required for operational safety.

In particular the connection between special features of a biomass heating 

system and his obligations as well as the warranty and guarantee terms must 

be explained. e.g. non-tested pellets and screw blockers, lack of cleaning or 

maintenance and stove malfunctions. Thorough instruction can prevent many 

complaints.

Stove functions

Explanation of the processes in the stove during ignition, normal operation, 

cleaning phase etc.

Control

Explain operator’s possibilities to intervene, empty pellet container, room 

thermostat, GSM modem, functions and settings, program times if necessary. 

Operating instructions: Handover and reference to the content to the following 

points, is a document.

Warranty terms

Difference between warranty (statutory) and guarantee (voluntary), terms of 

guarantee, determination of wearing parts, reference to pellet quality to be 

used and the consequences of poor quality.

Cleaning instructions

Ash and dust occurs with a biomass heating unit. The fire trough is to be 

cleaned regularly with regular heating operation (in the case of pellet operation, 

the drilled air holes in particular must be free of residues). The ash drawer is 

to be emptied regularly. The flue gas pipes are to be cleaned once or twice in 

the heating season depending on stove type; by a specialist company is best.

Maintenance

Maintenance work after defined burn-off output is to be performed by specialist 

company, including thorough cleaning.

Combustion

All doors must close tightly to prevent intake of false air.

Summary of Contents for Topo II

Page 1: ...TOPOII XL Operating Manual...

Page 2: ...perature shutdown 11 Electrical excess current protection 11 Component monitoring 11 Power failure during heating 11 Power failure during the initial stage 11 5 INSTALLING THE STOVE 12 General informa...

Page 3: ...TENANCE 25 Basic information 25 Cleaning the fire trough 25 Ampty the ash drawer 25 Cleaning the door glass 25 Cleaning flue pipes 26 Cleaning flue main duct 26 Cleaning the flue blower casing 27 Clea...

Page 4: ...Spare part overview exploded diagram till serial number 260821...

Page 5: ...5 EN 4...

Page 6: ...53 Z34401 Shale top dark 54 Z33958 Soapstone casing right 54 Z34400 Sandstone casing right Art Nr Description 54 Z34415 Shale right white 54 Z34402 Shale right dark 54 B16301 Soapstone casing right ti...

Page 7: ...on depends on the size of the pellets The larger the pellet the slower the feed and vice versa The owner of small firing systems or the person authorised for the small firing system is to keep the tec...

Page 8: ...mmable clothing is to be worn when post heating Q Placing non heat resistant objects on the stove or near it is prohibited Q Do not place clothing on the stove to dry Q Stands for drying clothes etc m...

Page 9: ...ions may be connected to your chimney Q Only use suitable tools from our range of accessories when handling embers and make sure that no embers fall out of the combustion chamber onto inflammable mate...

Page 10: ...1 10 arsenic content mg kg 1 1 cadmium content mg kg 1 0 5 mercury content mg kg 1 0 1 lead content mg kg 1 10 nickel content mg kg 1 10 zinc content mg kg 1 100 1 in an anhydrous state 2 diameter mu...

Page 11: ...ocked manually pressed The stove is ready for operation again after acknowledging the error message at the internal unit Note Maintenance and cleaning work must be performed if overheating occurs If t...

Page 12: ...e connection to the chimney has to be air tight Combustion air Every combustion process requires oxygen from the surrounding air This so called combustion air is removed from the living are in the cas...

Page 13: ...ft bases to prevent scratches to your living space furniture and stove panels Dismantling stone Open the convection cover so far that the cover securing mechanism locks into the designated retaining b...

Page 14: ...the left side cover You can now lift the left side cover and place it on a soft surface Re assemble the parts in reverse order Dismantling the right side trim Open the container lid Remove the hex sc...

Page 15: ...tatus returns to active or inactive active depressed inactive Input posibilities OFF Button Pressing the OFF button switches off the section concerned ON Button Pressing the ON button switches on the...

Page 16: ...ears after successful software update the stove must be disconnected from the mains and the USB stick removed First steps Once the stove has been reconnected to the mains the display changes to the da...

Page 17: ...following functions HOME status level Stove start stop setting heat output room set temperature current stove status display MODE operating mode level Selection of the required operating mode manual...

Page 18: ...er is activated is set in this submenu USB update This menu level concerns the software update of the stove Service not accessible to final customers Additional information for the specialist dealer o...

Page 19: ...s ON OFF 810 Output Th 15 03 2012 15 55 Ignition Grid Motor Air Control Box inc Discharge motor Current speed of screw motor conveying away from the pellet container range 0 1000 Feed motor Current sp...

Page 20: ...d settings HEATING TIMES This symbol is highlighted if individual heating times are activated ROOM SENSOR This symbol is highlighted if a functioning room sensor is connected FROST PROTECTION This sym...

Page 21: ...ove has an interface on the rear wall to which you can connect a customary room thermostat This requires a 2 pole cable of 0 5 0 75 mm cross section that you have to connect instead of the cable bridg...

Page 22: ...mperature is below the actual room temperature The pellet burner stop either outside the heating periods or if the desired room temperature is higher than the actual room temperature In the hibernatio...

Page 23: ...cur directly customer service is to be notified immediately In the case of error messages that pose a safety risk burnback and flue gas flap is activated and the stove is automatically switched off Wa...

Page 24: ...EFECT One of the two screw motors for pellet conveying can no longer be actuated Acknowledge error message and restart stove ERROR STL ACTIVATED The STL safety temperature limiter has activated The st...

Page 25: ...mineral content of the wood remains in the combustion chamber as ash as a residue of the combustion This is an excellent fertiliser for all plants in the garden it is a completely natural product The...

Page 26: ...ation Re assembly the parts removed in reverse order Cleaning flue main duct The flue main duct should be cleaned at least 2 x a year or after approx 700 kg pellets The flue main duct is located in th...

Page 27: ...he flue pipe from the flue gas fan and vacuum the flue gas fan housing Re assembly the parts removed in reverse order Cleaning the flame temperature sensor Remove the dust deposits from the sensor at...

Page 28: ...ompany Problem 2 Stove smells strongly and smokes outside Cause s Q Burning in phase taking into service Q Stove has accumulated dust and or dirt Possible solutions Q Wait to end of burning in phase a...

Page 29: ...hat are to be checked and ticked off The stove is ready for operation if these functions are ensured Operator instruction This is one of the most important points in the putting into operation It is v...

Page 30: ...tware version Warranty documents Touchdisplay version Door opener Electrical periphery Connection socket earthed GSM modem present Room thermostat present Function checked Check of system components C...

Page 31: ...urchase Connection must be performed by a specialist for such stoves Any costs incurred by the manufacturer due to unjustified warranty claims are to be charged to the claimant Wear parts and parts af...

Page 32: ...Ofentechnik GmbH 4563 Micheldorf Austria M llerviertel 20 Telefon 43 7582 686 41 Fax DW 43 E Mail verkauf rika at RIKA AT Technical and design changes as well as typesetting and printing errors reserv...