22
9. MODES
Note
When operating correctly, the stove may not be overheated. However
Improper operation can shorten the life expectancy of electrical components
(blowers, motors and electrical control) and is not allowed!
Pellet operation manual/automatic/comfort
MANUAL MODE
The pellet burner start and stop (ON / OFF button) and set the desired heat
output (PLUS / MINUS button) can be done on the touch screen directly at the
HOME main menu.
AUTOMATIC MODE
The exchange between standby and hibernation (ON / OFF button) and set the
desired heat output (PLUS / MINUS button) can be done on the touch screen
directly at the HOME main menu.
In AUTO mode, the heating times can be activated and the heating times can
be programmed.
The pellet burner start is in standby mode (ON) within the heating times (or
always at deactivated heating times).
The pellet burner stop is outside the heating times.
In the hibernation (OFF) no pellet burner start is possible, the system is turned
off.
COMFORT MODE
The exchange between standby and hibernation (ON / OFF button) and set the
desired room temperature (PLUS / MINUS button) can be done on the touch
screen directly at the HOME main menu.
In the COMFORT mode heating times can be additionally activated.
The pellet burner start is in standby mode (ON) within the heating times (or
always at deactivated heating times) and if the desired room temperature is
below the actual room temperature.
The pellet burner stop either outside the heating periods, or if the desired room
temperature is higher than the actual room temperature.
In the hibernation (OFF) no pellet burner start is possible, the system is turned
off.
Pellet container refilling
Note
CAUTION when filling! Don’t allow the pellet bag to get in contact with the hot
stove. Remove immediately pellets which have not found their way into the
reservoir!
In order to prevent the fire from extinguishingt due to a lack of pellets, we
recommend to keep an appropriate level in the reservoir upright. A 15 kg bag of
pellets can be filled into your stove when half of the pellets the pellet container
was consumed. See the level frequently. The container lid must, however,
always be kept closed except when filling.
When filling the container during operation (opening the container lid) the fan
starts up and pellet transport stops immediately, the operation will be resumed
after closing the container lid (see WARNINGS AND ERROR MESSAGES)
Pellet container capacity (see SPECIFICATIONS).
Emergency operation - heating up without
electrical Ignition
If the ignition cartridge fail, firelighters can be used for an emergency operation.
First, start the stove as usual. Wait for the turning of the grid (only for units with
turning grids). Then open the combustion chamber door and give a handful of
pellets with the igniter into the cleaned burn pot, light up this and close the
combustion chamber door.
Note
: Do not use flammable liquids to light up the fire!