background image

6

Spare part overview article numbers

#

Art.Nr.:

Description

1

N108131

pressure spring rotating grid

2

B15825

Hinge BA1

3

Z11915

lock ring conveyer screw

4

B16155

Induced draft fan housing

B15913

Induced draft fan cpl.

6

N111581

induced draught fan motor

7

B16521

Control panel

7

B16574

touch-Display

8

B15856

Motherboard C2 (for control panel)

8

B16561

mainboard USB11

9

B16030

additional board

10

L01598

Stone retaining bracket

11

L01752

Support stone bracket

12

B16302

Cleaning opening

13

B16265

Stone retainer

14

B16183

Screw

15

B16172

Connecting bend cpl.

16

B16251

Connecting bend for flue pipe outlet, side

17

L01611

Ash tray

18

Z35178

Inner lining, rear left

19

Z35179

Inner lining, rear right

20

Z35180

Inner lining, front left

21

Z35181

Inner lining, front right

22

Z34787

Inner lining, top front

23

Z34437

Flue plate

24

Z34788

Inner lining, top rear

25

Z33687

Grid

26

Z33924

intermediate shaft dump grate

27

L01581

Retaining plate

28

L01875

driving plate dump grate

29

Z33921

Recess

30

B16175

Drive shaft

B16178

Combustion chamber door cpl.

32

Z33695

Combustion chamber door

33

Z34123

Combustion chamber door (till nr.: 260 821)

34

Z33943

Door bracket, lower

35

Z33948

Door stop 1

36

Z33941

Door stop 2

37

Z33934

Stop bolt

38

Z33697

Decorative glass

39

Z34316

Combustion chamber door glass

40

Z34327

Cc-door glass (till serial nr.: 260 821)

41

Z34318

Glass retaining frame

42

Z34328

Glass retaining frame (till serial nr.: 260 821)

43

Z34329

Glass retaining frame (from serial nr.: 260 821)

44

Z33945

Glass retainer, upper

45

Z33946

Glass retainer, left

46

Z33947

Glass retainer, right

47

Z33944

Glass retainer, lower

48

L01606

Locking latch

49

Z33931

Locking bolt

50

Z33932

Glass insert

51

Z33976

Locking piece

52

L01648

Pressure bracket

53

Z33957

Soapstone casing, upper

53

Z34399

Sandstone casing, top

53

Z34414

Shale, top, white

53

Z34401

Shale, top, dark

54

Z33958

Soapstone casing, right

54

Z34400

Sandstone casing, right

#

Art.Nr.:

Description

54

Z34415

Shale, right, white

54

Z34402

Shale, right, dark

54

B16301

Soapstone casing, right (till serial nr.: 254 124)

55

LB00462

Rear panel cpl.

56

L01600

Cover rear panel

57

Z33950

Side casing panel, left

58

B16180

Side casing panel, right (for control panel)

58

B16883

Side casing panel, right (for TouchDisplay)

59

Z33936

Cover axis (Convection cover)

60

B16189

Convection cover

61

L01631

Cover securing mechanism

62

Z33935

Cover axis (Container cover)

63

B16186

Container cover

64

LB00517

Back panel cpl. (for Topo XL)

65

LB00518

back panel cover (for Topo XL)

66

N111828

Flat sealing strip 6x2, self-adhesive

67

N103693

culimeta flat packing black 8x2

68

N103693

culimeta flat packing black 8x2

69

N103066

Round sealing strip D06 (Recess)

70

N111631

round sealing cord grey Ø6mm

71

N100485

Round sealing strip D12

72

N111731

container seal

73

B16053

sensor tube

74

L01446

Lock washer

75

B16114

Temperature sensor

76

N111732

magnetic switch upper section

77

N111733

Solenoid switch lower part

78

B15396

Hinge

79

N111538

spring plug

80

N110447

Headless screw (catch limiter)

81

N100483

Hexagonal nut M10

82

N106283

Hexagonal nut M8

83

N111743

Knurled screw

84

N103981

Shaft locking clip D5

85

N104718

shaft securing device

87

N102434

Setscrew ( Glass insert)

89

N111825

door contact switch

90

N108131

pressure spring rotating grid

91

Z35183

Sintered bearing Di10

92

N111576

Switch cabinet key

93

N111820

Screw motor, stepless

94

N111751

Mudhole door motor

95

N111773

Levelling screw

96

N111781

Sealing ring (Glass insert)

97*

Z35182

Plastic bearing

98

B16947

Ceramic igniter with fuse 2,5 A

99

L01751

Foot adjusting key for levelling screw

100

Z34424

Rubber buffer

101

N111586

safety temperature limiter

102

N107887

fuse holder

103

N110461

double ball catch

B16202

Cable harness

B15981

Adapter cable for induced draft fan motor

Z35018

Cable touch display

Z35296

heat exchanger 1 (till serial number 307 998)

L01787

motor plate

Summary of Contents for Topo II

Page 1: ...TOPOII XL Operating Manual...

Page 2: ...perature shutdown 11 Electrical excess current protection 11 Component monitoring 11 Power failure during heating 11 Power failure during the initial stage 11 5 INSTALLING THE STOVE 12 General informa...

Page 3: ...TENANCE 25 Basic information 25 Cleaning the fire trough 25 Ampty the ash drawer 25 Cleaning the door glass 25 Cleaning flue pipes 26 Cleaning flue main duct 26 Cleaning the flue blower casing 27 Clea...

Page 4: ...Spare part overview exploded diagram till serial number 260821...

Page 5: ...5 EN 4...

Page 6: ...53 Z34401 Shale top dark 54 Z33958 Soapstone casing right 54 Z34400 Sandstone casing right Art Nr Description 54 Z34415 Shale right white 54 Z34402 Shale right dark 54 B16301 Soapstone casing right ti...

Page 7: ...on depends on the size of the pellets The larger the pellet the slower the feed and vice versa The owner of small firing systems or the person authorised for the small firing system is to keep the tec...

Page 8: ...mmable clothing is to be worn when post heating Q Placing non heat resistant objects on the stove or near it is prohibited Q Do not place clothing on the stove to dry Q Stands for drying clothes etc m...

Page 9: ...ions may be connected to your chimney Q Only use suitable tools from our range of accessories when handling embers and make sure that no embers fall out of the combustion chamber onto inflammable mate...

Page 10: ...1 10 arsenic content mg kg 1 1 cadmium content mg kg 1 0 5 mercury content mg kg 1 0 1 lead content mg kg 1 10 nickel content mg kg 1 10 zinc content mg kg 1 100 1 in an anhydrous state 2 diameter mu...

Page 11: ...ocked manually pressed The stove is ready for operation again after acknowledging the error message at the internal unit Note Maintenance and cleaning work must be performed if overheating occurs If t...

Page 12: ...e connection to the chimney has to be air tight Combustion air Every combustion process requires oxygen from the surrounding air This so called combustion air is removed from the living are in the cas...

Page 13: ...ft bases to prevent scratches to your living space furniture and stove panels Dismantling stone Open the convection cover so far that the cover securing mechanism locks into the designated retaining b...

Page 14: ...the left side cover You can now lift the left side cover and place it on a soft surface Re assemble the parts in reverse order Dismantling the right side trim Open the container lid Remove the hex sc...

Page 15: ...tatus returns to active or inactive active depressed inactive Input posibilities OFF Button Pressing the OFF button switches off the section concerned ON Button Pressing the ON button switches on the...

Page 16: ...ears after successful software update the stove must be disconnected from the mains and the USB stick removed First steps Once the stove has been reconnected to the mains the display changes to the da...

Page 17: ...following functions HOME status level Stove start stop setting heat output room set temperature current stove status display MODE operating mode level Selection of the required operating mode manual...

Page 18: ...er is activated is set in this submenu USB update This menu level concerns the software update of the stove Service not accessible to final customers Additional information for the specialist dealer o...

Page 19: ...s ON OFF 810 Output Th 15 03 2012 15 55 Ignition Grid Motor Air Control Box inc Discharge motor Current speed of screw motor conveying away from the pellet container range 0 1000 Feed motor Current sp...

Page 20: ...d settings HEATING TIMES This symbol is highlighted if individual heating times are activated ROOM SENSOR This symbol is highlighted if a functioning room sensor is connected FROST PROTECTION This sym...

Page 21: ...ove has an interface on the rear wall to which you can connect a customary room thermostat This requires a 2 pole cable of 0 5 0 75 mm cross section that you have to connect instead of the cable bridg...

Page 22: ...mperature is below the actual room temperature The pellet burner stop either outside the heating periods or if the desired room temperature is higher than the actual room temperature In the hibernatio...

Page 23: ...cur directly customer service is to be notified immediately In the case of error messages that pose a safety risk burnback and flue gas flap is activated and the stove is automatically switched off Wa...

Page 24: ...EFECT One of the two screw motors for pellet conveying can no longer be actuated Acknowledge error message and restart stove ERROR STL ACTIVATED The STL safety temperature limiter has activated The st...

Page 25: ...mineral content of the wood remains in the combustion chamber as ash as a residue of the combustion This is an excellent fertiliser for all plants in the garden it is a completely natural product The...

Page 26: ...ation Re assembly the parts removed in reverse order Cleaning flue main duct The flue main duct should be cleaned at least 2 x a year or after approx 700 kg pellets The flue main duct is located in th...

Page 27: ...he flue pipe from the flue gas fan and vacuum the flue gas fan housing Re assembly the parts removed in reverse order Cleaning the flame temperature sensor Remove the dust deposits from the sensor at...

Page 28: ...ompany Problem 2 Stove smells strongly and smokes outside Cause s Q Burning in phase taking into service Q Stove has accumulated dust and or dirt Possible solutions Q Wait to end of burning in phase a...

Page 29: ...hat are to be checked and ticked off The stove is ready for operation if these functions are ensured Operator instruction This is one of the most important points in the putting into operation It is v...

Page 30: ...tware version Warranty documents Touchdisplay version Door opener Electrical periphery Connection socket earthed GSM modem present Room thermostat present Function checked Check of system components C...

Page 31: ...urchase Connection must be performed by a specialist for such stoves Any costs incurred by the manufacturer due to unjustified warranty claims are to be charged to the claimant Wear parts and parts af...

Page 32: ...Ofentechnik GmbH 4563 Micheldorf Austria M llerviertel 20 Telefon 43 7582 686 41 Fax DW 43 E Mail verkauf rika at RIKA AT Technical and design changes as well as typesetting and printing errors reserv...

Reviews: