INSTALLER : THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.

CERTIFIED IN CANADA TO CAN/CSA C22.2 NO. B140.3, B140.1, B140.0 AND IN THE UNITED STATES CONFORMS TO UL Std 307a, ANSI/ULStd 896

INSTALLATION AND OPERATION INSTRUCTIONS
FOR
OIL-FIRED CAST IRON STOVE
MOBILE HOME APPROVED

MODEL

SAVOY OS11

Document n° 1043-1 ~ 15/01/2002

Installation and Service must be performed by a Qualified Installer, Service Agency or the Oil Supplier

WOLF STEEL LTD., RR#1, 24 NAPOLEON RD.,

BARRIE, ON., CANADA L4M 4Y8 (705)721-1212

Fax: (705)722-6031

Email : [email protected]

Web: WWW.NAPOLEONFIREPLACE.COM

Summary of Contents for SAVOY OS11

Page 1: ...ULStd 896 INSTALLATION AND OPERATION INSTRUCTIONS FOR OIL FIRED CAST IRON STOVE MOBILE HOME APPROVED MODEL SAVOY OS11 Document n 1043 1 15 01 2002 Installation and Service must be performed by a Quali...

Page 2: ...rea such as an attic a basement or a garage Do not use this stove if any part has been under water immediately call a qualified service technician to inspect the stove and to replace any part of the c...

Page 3: ...r any scratches dents corrosion or discolouring caused by excessive heat abrasive and chemical cleaners nor chipping on porcelain enamel parts nor any venting components used in the installation of th...

Page 4: ...son for dirty glass is running the unit at a low burning rate If it is necessary to clean the glass use a soft cloth with a nonabrasive cleaner Coarse cleaning materials may cause scratches or otherwi...

Page 5: ...e the chimney draft To alter one of them will affect the other two and change the amount of draft in the chimney and ultimately the stove s performance To ensure that adequate chimney draft is maintai...

Page 6: ...HIMNEY HEIGHT ABOVE THE STOVE TO A MAXIMUM HORIZONTAL RUN OF 10 FEET All smoke pipe must slope upwards at a minimum of 1 4 per foot 6 mm 300 mm and all connections must be tight and secured by three s...

Page 7: ...s must be placed on the bottom of each framed opening in any floor or ceiling that the chimney passes through figure 5 3 Hold a plumb bob from the underside of the roof to determine where the opening...

Page 8: ...etor to use only a specific category of fuel oil This fuel oil must be clean and free of any dirt or traces of water Impurities in the fuel oil can cause a reduced efficiency level The only fuel to be...

Page 9: ...utlet 1 Blanking plate 2 Burner 3 Flue collar 4 Baffle 5 Reflector 6 Optional mirrors Figure 14 Operating devices 1 Control knob 2 Intake collar 3 Safety lever 4 Control filter access 5 Min setting ad...

Page 10: ...ation except during lighting procedures Proceed once installation is complete and all necessary instructions have been followed When lit for the first time the stove will emit a slight odour for a few...

Page 11: ...f the flame is too high reduce the oil flow by turning the set screw counter clockwise The flames should be blue with occasional yellow tips The catalyser should glow red Adjustment at maximum speed G...

Page 12: ...d be removed YEARLY CHIMNEY MAINTENANCE The chimney is to be swept at least once a year It is also recommended that prior to every heating season the entire system be professionally inspected cleaned...

Page 13: ...5 1 60 m 23 188820 Ceramic glass 01 24 189118 Brass screw d 10 01 25 189825 Screw M5x6 01 26 194401 Catalyser cover 01 27 194402 Catalyser body 01 28 198205 Catalyser ring 01 29 199204 Regulator filte...

Page 14: ...5 2 6 2 7 2 8 2 9 3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 4 1 4 2 4 3 4 4 4 5 4 6 4 7 4 8 4 9 5 0 5 1 5 2 5 3 5 4 5 5 5 6 5 7 5 8 5 9 6 2 6 4 2 0 4 0 6 5 6 1 6 0 1 0 6 0 6 0 1 6 3 5 5 5 5 3 3 5 5 6 0...

Page 15: ...Notes Document n 1043 1 15 01 2002 15...

Page 16: ...ur installer Insufficient fuel Check that the de scaler the carburetor filter and burner pot are cleaned Fire smokes Soot build up noticed Flame imbalance Insufficient air supply Increase fresh air su...