SYMPTOM

PROBLEM

TEST SOLUTION

Flames extinguish during lighting.

Very cold chimney. No draft
established

- Leave door ajar until fire has caught.
- check air supply in the room

Fire extinguishes once firestarter has
burnt off.

Fuel tank is empty

- Fill tank

Fuel valve is closed.

- Open valve

Main carburetor float not engaging.

- De-press the safety lever

Control knob is set on “0"

- Adjust control knob to ”1"

Fire extinguishes during use.

Fuel tank is empty.

- Fill tank

Insufficiant draft

- Call your installer

Flame is excessely large, smokey and
sooty.

Fuel adjustment made too quickly.

- Return control knob to “1" ; wait for
normal combustion. (catalyser should
glow red).

- Wait 5 to 15 minutes between each
adjustment.

Stove burns noisily, extinguishes and
relights itself.

Burner contains excess fuel

- Adjust to lower setting. If problem
persists call your installer.

Insufficient fuel

- Check that the de-scaler, the
carburetor filter and burner pot are
cleaned.

Fire smokes.Soot build up noticed.
Flame imbalance

Insufficient air supply.

- Increase fresh air supply (open door,
window ; add make up air supply)

Downdraft or blockage in chimney

- Check Chimney for Soot build up.
clean if necessary.

- Ensure chimney height is sufficient
and cap is not affected by any nearby
obstructions.

- Room is in negative pressure.
Increase fresh air supply. Check draft
with draft meter and adjust if not to
requirements. See page 5.

Oil flow is too low on setting.

- Adjust low flow rate while control is
set on “1", call your installer.

Stove is not level. Flame imbalance.

Check level. Adjust if necessary.

Catalyser not centered. Uneven fuel
distribution resulting in secondary air
shortage.

Center catalyser assembly

Insufficient fuel

- Check that the de-scaler, the
carburetor filter and burner pot are
cleaned.

Coke build up noticed.

Excessive air supply.

- Adjust draft.

TROUBLE SHOOTING

Do

cume

nt

10

43-1

~

15

/01

/20

02

16

Summary of Contents for SAVOY OS11

Page 1: ...ULStd 896 INSTALLATION AND OPERATION INSTRUCTIONS FOR OIL FIRED CAST IRON STOVE MOBILE HOME APPROVED MODEL SAVOY OS11 Document n 1043 1 15 01 2002 Installation and Service must be performed by a Quali...

Page 2: ...rea such as an attic a basement or a garage Do not use this stove if any part has been under water immediately call a qualified service technician to inspect the stove and to replace any part of the c...

Page 3: ...r any scratches dents corrosion or discolouring caused by excessive heat abrasive and chemical cleaners nor chipping on porcelain enamel parts nor any venting components used in the installation of th...

Page 4: ...son for dirty glass is running the unit at a low burning rate If it is necessary to clean the glass use a soft cloth with a nonabrasive cleaner Coarse cleaning materials may cause scratches or otherwi...

Page 5: ...e the chimney draft To alter one of them will affect the other two and change the amount of draft in the chimney and ultimately the stove s performance To ensure that adequate chimney draft is maintai...

Page 6: ...HIMNEY HEIGHT ABOVE THE STOVE TO A MAXIMUM HORIZONTAL RUN OF 10 FEET All smoke pipe must slope upwards at a minimum of 1 4 per foot 6 mm 300 mm and all connections must be tight and secured by three s...

Page 7: ...s must be placed on the bottom of each framed opening in any floor or ceiling that the chimney passes through figure 5 3 Hold a plumb bob from the underside of the roof to determine where the opening...

Page 8: ...etor to use only a specific category of fuel oil This fuel oil must be clean and free of any dirt or traces of water Impurities in the fuel oil can cause a reduced efficiency level The only fuel to be...

Page 9: ...utlet 1 Blanking plate 2 Burner 3 Flue collar 4 Baffle 5 Reflector 6 Optional mirrors Figure 14 Operating devices 1 Control knob 2 Intake collar 3 Safety lever 4 Control filter access 5 Min setting ad...

Page 10: ...ation except during lighting procedures Proceed once installation is complete and all necessary instructions have been followed When lit for the first time the stove will emit a slight odour for a few...

Page 11: ...f the flame is too high reduce the oil flow by turning the set screw counter clockwise The flames should be blue with occasional yellow tips The catalyser should glow red Adjustment at maximum speed G...

Page 12: ...d be removed YEARLY CHIMNEY MAINTENANCE The chimney is to be swept at least once a year It is also recommended that prior to every heating season the entire system be professionally inspected cleaned...

Page 13: ...5 1 60 m 23 188820 Ceramic glass 01 24 189118 Brass screw d 10 01 25 189825 Screw M5x6 01 26 194401 Catalyser cover 01 27 194402 Catalyser body 01 28 198205 Catalyser ring 01 29 199204 Regulator filte...

Page 14: ...5 2 6 2 7 2 8 2 9 3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 4 1 4 2 4 3 4 4 4 5 4 6 4 7 4 8 4 9 5 0 5 1 5 2 5 3 5 4 5 5 5 6 5 7 5 8 5 9 6 2 6 4 2 0 4 0 6 5 6 1 6 0 1 0 6 0 6 0 1 6 3 5 5 5 5 3 3 5 5 6 0...

Page 15: ...Notes Document n 1043 1 15 01 2002 15...

Page 16: ...ur installer Insufficient fuel Check that the de scaler the carburetor filter and burner pot are cleaned Fire smokes Soot build up noticed Flame imbalance Insufficient air supply Increase fresh air su...

Reviews: