![Rigol DSG5000 Series Programming Manual Download Page 70](http://html.mh-extra.com/html/rigol/dsg5000-series/dsg5000-series_programming-manual_1460929070.webp)
Parameter
Name
Type
Range
Default
<channel>
Discrete
1|2|3|4|5|6|7|8
1
<Index>
Integer
1 to total number of lines in the
current pulse list
-
Remarks
•
<Index> denotes the line number of the pulse list.
•
This command allows you to delete one line of pulse values. The
command allows you to add one line of pulse
values.
Return Format
N/A
Example
:PULM:TRA:LIST:DEL 2 /*Deletes the second line of pulse values
from the current pulse list (by default, CH1 is selected).*/
3.1.9.10
[:SOURce][:RF]:PULM:TRAin:LIST:GET
Syntax
[:SOURce][:RF
<
channel>
]:PULM:TRAin:LIST:GET?
<
Start>,<Count>
Description
Acquires the pulse list within the specified range for the specified channel.
Parameter
Name
Type
Range
Default
<channel>
Discrete
1|2|3|4|5|6|7|8
1
<Start>
Integer
1 to total number of lines in the
current pulse list
-
<Count>
Integer
1 to total number of lines in the
current pulse list
-
Command System
62
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.