![Rigol DSG5000 Series Programming Manual Download Page 49](http://html.mh-extra.com/html/rigol/dsg5000-series/dsg5000-series_programming-manual_1460929049.webp)
•
OFF: turns off the AM switch to disable the AM function.
Return Format
The query returns 1 or 0.
Example
:RF2:AM:STAT ON /*Turns on the AM switch to enable the AM
function for CH2.*/
:RF2:AM:STAT? /*The query returns 1.*/
3.1.6.5
[:SOURce][:RF]:AM:SOURce
Syntax
[:SOURce][:RF
<
channel>
]:AM:SOURce
<
type>
[:SOURce][:RF
<
channel>
]:AM:SOURce?
Description
Sets the AM modulation source type of the specified channel.
Queries the AM the modulation source type of the specified channel.
Parameter
Name
Type
Range
Default
<channel>
Discrete
1|2|3|4|5|6|7|8
1
<type>
Discrete
EXTernal|INTernal
INTernal
Remarks
•
EXTernal: selects the external modulation source. At this point, the external
modulating signal is input from the [EXT MOD IN] connector.
•
INTernal: selects the internal modulation source. At this point, the instrument
provides the modulating signal. You can run the
command and the
command to set the
modulation frequency and modulation waveform of the modulating signal.
Return Format
The query returns the AM modulation source type of the specified channel.
Command System
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
41