TECHNICAL ASSISTANCE SERVICE
3 .10
Conversion from one gas type to another
The
TAU 35 UNIT
boiler comes configured for use with
G20 (methane) gas. The boiler can also be converted for
use with G31 gas (LPG) using the conversion kit provided.
9
Note that all modifications to the gas feed system
are forbidden in Belgium.
In Belgium, contact
R
’s Technical Assistance
Service.
Before starting any conversion work:
− Switch the electricity supply OFF at the system’s
main switch and at the control panel
− Close the gas shut-off cock
− Loosen the screw (3) and remove the gas valve (1)
from the venturi assembly (2)
− Remove the diaphragm (4) from the gas valve
and fit the one supplied inside the “Warranty”
envelope
− The table alongside shows the diaphragm dia-
meter required for the different gas types and
boiler models.
− Fit the valve gas back and perform the necessary
calibrations as instructed in the section “Calibra-
ting combustion parameters” on page 46.
9
The following pressures are required from the gas
supply:
−
G20 gas = 20 mbar
−
G31 gas = 37 mbar
9
Conversions must only be performed by qualified
personnel from
R
’s Technical Assistance Service,
even after the boiler has been installed.
9
On completion of the conversion, adjust the boiler
following the instructions given in the “Calibrating
combustion parameters” section of this manual.
1
2
3
4
TAU 35 UNIT
G20
7
G31
4,5
Calibrated diaphragm diameter (Ø)