TECHNICAL ASSISTANCE SERVICE
3 .9
Complete list of parameters
LIST OF END USER LEVEL PARAMETERS
N°
Description
Range
U/M
Default
www
1
Time of day
0…23.59
h/min
---
Setpoints
5 (*)
Line 5 will be hidden when using an additional room unit:
Reduced room temperature setpoint
10…30
°C
20
Reduced boiler temperature setpoint
30...boiler temperature setpoint
CH circuit 1 program
11
Switch-on time 1st phase
00:00…24:00
hh:mm
06:00
12
Switch-off time 1st phase
00:00…24:00
hh:mm
22:00
13
Switch-on time 2nd phase
00:00…24:00
hh:mm
24:00
14
Switch-off time 2nd phase
00:00…24:00
hh:mm
24:00
15
Switch-on time 3rd phase
00:00…24:00
hh:mm
24:00
16
Switch-off time 3rd phase
00:00…24:00
hh:mm
24:00
DHW program (only used in conjunction with a storage cylinder)
31
Time program DHW, 1st phase on
00:00…24:00
hh:mm
06:00
32
Time program DHW, 1st phase off
00:00…24:00
hh:mm
22:00
33
Time program DHW, 2nd phase on
00:00…24:00
hh:mm
24:00
34
Time program DHW, 2nd phase off
00:00…24:00
hh:mm
24:00
35
Time program DHW, 3rd phase on
00:00…24:00
hh:mm
24:00
36
Time program DHW, 3rd phase off
00:00…24:00
hh:mm
24:00
45
Standard time programs for HC and DHW
No/Yes
---
No
(press simultaneously buttons
-
and
+
for 3 seconds)
516
Summer / winter changeover temperature
8…30
°C
20
(30=changeover deactivated)
520
PARAMETER FIXED IN THIS MODEL
DO NOT CHANGE SETTING
10
629
Enduser can acknowledge a pending maintenance alarm via this
parameter
(0 / 1 = disabled/ena-
bled)
0
726
Maintenance code contains enumeration value of maintenance
alarm (exact cause)
0…255
0
(*)
Outdoor temperature sensor connected: set the room temperature reduced setpoint.
Outdoor temperature sensor not connected: set the boiler temperature reduced setpoint.