13
2. SECTION - TECHNICAL DATA
2.1
Central Heating
UNICA MAX 35C
UNICA MAX 40C
Heat input (kW)
32.00
32.00
Maximum heat output (kW) 60/80°C
31.23
31.23
Minimum heat output (kW) 60/80°C
4.69
4.69
Maximum heat output (kW) 30/50°C
34.37
34.37
Minimum heat output (kW) 30/50°C
5.06
5.06
Minimum working pressure
0.25÷0.45 bar
Maximum working pressure
2.5 bar
Minimum flow rate
350 l/h
2.2
Domestic Hot Water
UNICA MAX 35C
UNICA MAX 40C
Heat input (kW)
34.60
40.00
Flow Rate: ΔT35°C
14.9
16.4
Maximum inlet pressure
8 bar
Minimum inlet pressure
0.2 bar
Minimum flow rate
2 l/min
Flow regulator
12 l/min
14 l/min
2.3
Gas Pressures
UNICA MAX 35C
UNICA MAX 40C
Inlet pressure (G20)
20.0 mbar
20.0 mbar
Heating maximum gas rate (m
3
/hr)
3.38
3.38
DHW maximum gas rate (m
3
/hr)
3.66
4.23
Minimum gas rate (m
3
/hr)
0.52
0.52
Injector size (mm)
5.2
5.2
2.4
Expansion Vessel
UNICA MAX 35C
UNICA MAX 40C
Capacity
10 litres
Maximum system volume
74 litres
Pre-charge pressure
1 bar
2.5
Dimensions
UNICA MAX 35C
UNICA MAX 40C
Height (mm)
740
Width (mm)
470
Depth (mm)
350
Dry weight (kg)
39,5
39,5
2.6
Clearances required for maintenance
UNICA MAX 35C
UNICA MAX 40C
Sides
2mm*
Top
100mm** from casing or 25mm above flue elbow (whichever is applicable)**
Bottom
100mm^
Front
450mm^^
* It may be necessary to remove adjacent components if component removal/replacement is required
** Consideration should be given to providing reasonable clearance for the insertion of a FGA probe.
^ This can be reduced to 4mm if a removal panel enables the required 100mm
^^ When installed in a cupboard, this dimension can be reduced to 4mm provided that the required 450mm is available when the door is opened/
removed.
2.7
Connections
UNICA MAX 35C
UNICA MAX 40C
Flow & return
22mm
Gas
15mm
DHW hot & cold
15mm
Safety valve
15mm
Condense
21mm
2.8
Electrical
UNICA MAX 35C
UNICA MAX 40C
Power consumption CH (Watts)
101
Power consumption DHW (Watts)
112
Voltage (V/Hz)
230/50
Internal fuse
4 A T (for PCB) - 3.15A F (for connections block)
External fuse
3A
2.9
Flue Details (concentric 60-100)
UNICA MAX 35C
UNICA MAX 40C
Maximum horizontal flue length (60/100mm)
6.0 m
6.0 m
Maximum vertical flue length (60/100mm)
7.0 m
7.0 m
2.10 Efficiency
UNICA MAX 35C
UNICA MAX 40C
SEDBUK 2005 (%)
90.1
90.1
2.11 Emissions
UNICA MAX 35C
UNICA MAX 40C
CO2 @ maximum output (%) (*)
9.0
9.0
CO2 @ minimum output (%) (*)
9.0
9.0
CO @ maximum output (ppm)
170
170
CO @ minimum output (ppm)
10
10
NOx rating
class 6
class 6
(*) CO
2
tolerance= +0.6% -1%