3. SECTION - CONTROL PANEL (REC10CH)
Pressing the keys
“up”
and
“down”
it is possible to choose
from among the following options:
•
PLANT:
the display will indicate the temperature of the
domestic hot water sensor rather than the flow sensor of
the boiler
•
STATE/BOILER:
enables access to choose the operating
mode of the appliance: OFF, Summer, Winter
•
STATE/MAIN ZONE
(if embedded clock disabled)
:
enables
access to choose the operating mode (On or OFF) of the
main heating zone
•
STATE/MAIN ZONE
(if embedded clock is enabled)
:
enables access to choose operating mode of the embedded
clock (AUTO, MANUAL, OFF)
•
SET:
to view or adjust the heating or hot water setpoint
value or to enable or disable preheating
•
INFO:
to view the current values or status of the various
appliance inputs/sensors
•
MENU:
to access the system’s configuration menus
The REC10CH is a fully functional UI (User Interface) that acts as a visual reference for the appliance and system status; and
can also be used to view, input and adjust relevant system parameters and functions (also for solar system and heat pump if
present).
The centre of the UI will normally display the current operating temperature (according to the mode of operation); however when
the screensaver is active, the current time will be displayed.
The value expressed in bar refers to the system’s water pressure.
The top of the screen shows the information regarding the current date and time, as well as the outdoor temperature, if available.
On the left and right sides are displayed the icons indicating the status of the system; their meaning is as follows.
REC10CH
Boiler control panel
Key area
Confirm
back= return to the previous screen
cancel selection
return to the main screen (press > 2 sec.)
- From the main screen they allow you to choose between
the options: MENU, INFO, SET, STATE, PLANT.
- From the sub-menus they allow you to navigate through
the different options
This icon indicates that the OFF operating status mode has been set. Each ignition request is ignored except for the frost-protection
function. The pump anti-lock, 3-way valve and frost-protection function remain active.
This icon indicates that WINTER mode has been selected (HEATING function enabled). If a heating request from the main zone is in
progress, the icon will be flashing.
If there is a CH request from the additional zone, the number 1 or 2 is flashing.
Only if heat pump is present.
This icon indicates that cooling is active in the SUMMER state. If a cooling request from the main
zone is in progress, the icon is flashing. If a cooling request from the additional zone is in progress, number 1 is flashing.
This icon indicates that the circuit for domestic hot water production is enabled. When a domestic hot water request is in progress, the
icon flashes. The
“P”
at the top of the domestic hot water icon indicates that the boiler preheating function is enabled; the
“P”
when
flashing indicates that a preheating request is in progress.
When the “central heating programming timing” is enabled this icon indicates that the system heating (main zone) is in AUTOMATIC
mode (the management of the heating requests follows what has been set with the timer).
If the heating function is not enabled during the current time frame, the icon will be crossed out.
When the “central heating programming timing” is enabled this icon indicates that the system heating (main zone) is in MANUAL mode
(the management of the heating requests does not follow what has been set with the programming timing, but it is always active).
OFF
This icon indicates that the main zone, when the “central heating programming timing” function is not enabled, has been set to off
(not active).
Only if heat pump is present.
This icon indicates that the management of a heat pump is enabled. When the heat pump is
running, then the icon is flashing.
Only if solar system is present.
This icon indicates that the management of a solar system is enabled. When the solar system
circulator is running, then the icon is flashing.
This icon indicates that the system is detecting the presence of a flame.
This icon indicates the presence of an anomaly or fault condition, and is always flashing.
Only with combined boiler and presence of heat pump enabled for domestic hot water.
The icon appears crossed
out with an “X” when the system works outside the activation times of the heat pump in the domestic hot water, while it flashes
when the heat pump is in operation to load the boiler.
Only if photovoltaic enabled.
When the icon is flashing, it means that the electrical productivity of the photovoltaic system is
adequate (closed contact). The system exploits the available energy.
FRI
18/05/2021
12:17
MENU
INFO
SET
PLANT
HOT WATER TEMPERATURE
STATE
42
°C
P
1
2
1.3 bar