16
Key
Location
Minimum distance
A
Below an opening (window, air-brick, etc.)
300 mm
B
Above an opening (window, air-brick, etc.)
300 mm
C
To the side of an opening (window, air-brick, etc.)
300 mm
D
Below gutter, drain-pipe, etc.
25 mm
E
Below eaves
25 mm
F
Below balcony, lowest point of carport roof, etc.
25 mm
G
To the side of a soil/drain-pipe, etc.
25 mm (60mm for 80/125mm)
H
From internal/external corner
25 mm (60mm for 80/125mm)
I
Above ground, roof, or balcony level
300 mm
J
From a surface or boundary facing the terminal
600 mm*
K
From a terminal facing a terminal
1200 mm
L
From an opening in the car-port into the building
1200 mm
M
Vertically from a terminal on the same wall
1500 mm
N
Horizontally from a terminal on the same wall
300 mm
P
From a structure to the side of the vertical terminal
300 mm
Q
From the top of the vertical terminal to the roof flashing
As determined by the fixed collar
of the vertical terminal
R
To the side of a boundary
300 mm
S
To the side of an opening or window on a pitched roof
600 mm
T
Below an opening or window on a pitched roof
2000 mm
V
From a vertical terminal to an adjacent opening (window, air-brick, etc.)
2000 mm
W
From a vertical terminal to an adjacent vertical terminal
300 mm (only if both terminals are the same height)
Fig. 5
*The possibility that this may be deemed as causing a nuisance, should be considered