When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance 

specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by Ideal Boilers.

For the very latest copy of literature for specification and maintenance practices visit our website www.idealboilers.com  

where you can download the relevant information in PDF format.

February 2019

UIN 215350 A09

USER GUIDE

LOGIC SYSTEM 

S15IE S18IE S24IE S30IE

Summary of Contents for S15IE

Page 1: ... Do not use reconditioned or copy parts that have not been clearly authorised by Ideal Boilers For the very latest copy of literature for specification and maintenance practices visit our website www idealboilers com where you can download the relevant information in PDF format February 2019 UIN 215350 A09 USER GUIDE LOGIC SYSTEM S15IE S18IE S24IE S30IE ...

Page 2: ...rence should be made to the current ETCI rules for electrical installation It is essential that the instructions in this booklet are strictly followed for safe and economical operation of the boiler ELECTRICITY SUPPLY This appliance must be earthed Supply 230 V 50 Hz The fusing should be 3A IMPORTANT NOTES This appliance must not be operated without the casing correctly fitted and forming an adequ...

Page 3: ...our boiler efficiently using less gas turn the central heating temperature knob A to the position or lower In winter periods it may be necessary to turn the knob towards the MAX position to meet heating requirements This will depend on the house and radiators used Reducing the room thermostat setting by 1ºC can reduce gas consumption by up to 10 WEATHER COMPENSATION When the Weather Compensation o...

Page 4: ...all your Gas Safe Registered engineer Preventative solutions During cold weather set the central heating temperature knob A to maximum Must return to original setting once cold spell is over Place the heating on continuous and turn the room thermostat down to 15ºC overnight or when unoccupied Return to normal after cold spell 4 LOSS OF SYSTEM WATER PRESSURE The gauge G indicates the central heatin...

Page 5: ...rogrammer are as you require and adjust if necessary Check the programmer external to the boiler is in an ON position and the hot water cylinder thermostat is turned up NO See boiler Operation Modes and Fault Codes section If 00 is displayed then contact a Gas Safe Registered Engineer or in IE a Registered Gas Installer RGII 6 POINTS FOR THE BOILER USER Note In line with our current warranty polic...

Page 6: ...r central heating but the appliance has reached the desired temperature set on the boiler The boiler is operating in central heating hot water mode The boiler is operating in frost protection 7 NORMAL OPERATION DISPLAY CODES The boiler mode knob B is in the off position rotate fully clockwise for hot water and central heating operation FP 54 00 54 o C o C ON ON ...

Page 7: ...as Safe Registered Engineer if outside of the warranty period In IE contact a Registered Gas Installer RGII 1 Check condensate Pipe for blockages refer to Section 3 2 Check other gas appliances in the house are working to confirm a supply is present in the property 3 If other appliances do not work or there are no other appliances check the gas supply is on at the meter and or pre payment meter ha...

Page 8: ......

Reviews: