3.3.1.9
Contact start
Contact start active
Start time
End time
Start level for contact start
Influence active
Cont. value for start influence
Cont. value for end influence
Max. influence on irrigation cycle
Central contact
Ignore main pause time
Contact start active
No: Not active.
Yes: Active.
Start time of contact start
The time after which a contact start may take place:
Real time: fixed point in time.
Sunrise: time before (-) or after sunrise.
Sunset: time before (-) or after sunset.
End time of contact start
The time after which a contact start may no longer take place.
Real time: fixed point in time.
Sunrise: time before (-) or after sunrise.
Sunset: time before (-) or after sunset.
No start will be executed if 00:00:00 (real time) is set for the end time.
Start level for contact start 0 - 100 %
The level, as a percentage of the measuring range, above or below which a contact
start will be executed.
Influence active
Enables you to activate the contact value influence on the size of an irrigation cycle
(i.e. the amount of water applied during that cycle).
This influence is also applied if the irrigation cycle was triggered by another type of
start than a contact start.
Remarks:
If the contact input is an analogue signal, you can select a number of different
contact types.
The contact input provides the measured value for the influence. This influence
is applied not only when a contact start occurs, but also other types of starts.
Aqua CX300
37