The figure below of the Valve settings screen shows that valve 1 has been assigned to
valve groups 3 and 4. Sequence number 10 has been set for the first valve group (i.e.
valve group 3) and sequence number 20 has been set for the second valve group (i.e.
valve group 4).
Figure 3-3
Sequence in second valve group
This looks as follows on the assign valves screen:
Figure 3-4
Selected valves
As you can see, valve 1 has first been assigned to valve group 3 and has then been
assigned to valve group 4. A valve sequence cannot be entered or displayed on this
screen.
To add a valve, place the cursor on the desired valve and then press <E>. Since a
valve can be assigned to two valve groups (so two settings), it is added to the first
available position. (This is value 0 on the Valve settings screen, and '1: G—’ is
displayed on the assign valves screen.)
To add the valve to the first or second position, press <1> or <2> . These positions
are important if you are going to set a valve sequence.
When valve group 3 is activated, the controller will open all the valves for which the
first and second valve group numbers are set to 3.
Aqua CX300
18