EXAMPLE
Vlv1 Vlv2 Vlv3 Vlv4 Vlv5 Vlv6 Vlv7 Vlv8
First valve group
number
GR3
GR3
GR4
GR4
GR4
Second valve group
number
GR4
GR3
GR3
When Group 3 is activated, valves 1,2,5 and 6 will open to supply water.
To set a valve sequence, the ‘Set valve sequence’ function must first be enables on
the configuration screen. You can then enable the ‘Set valve sequence’ function for
each program individually.
Figure 3-5
Setting valve sequence
If you enable the ‘Set valve sequence’ function, the controller will use the ‘Sequence
in first valve group’ for the first valve group number and the ‘Sequence in second
valve group’ for the second valve group number.
Vlv1 Vlv2 Vlv3 Vlv4 Vlv5 Vlv6 Vlv7 Vlv8
First valve group
number
GR3
GR3
GR4
GR4
GR4
Second valve group
number
GR4
GR3
GR3
Sequence in first
valve group
10
9
0
0
20
0
0
0
0 0
Sequence in second
valve group
20
0
0
0
0
7
0
0
0 0
When Group 3 is activated, the valves will open to supply water in this sequence: 5, 6,
2, 1.
When Group 4 is activated, the valves will open to supply water in this sequence: 6, 7,
5.
Aqua CX300
19