Alarm of external pH control, group continued
External pH control has triggered an alarm. As a result, pH control has stopped and
the valve group has continued irrigation with fresh water.
Check pH control.
5.5
Contact sensors
Sensor alarm contact 1
Sensor alarm contact 10
The input signal of the contact start has been exceeded.
Check the contact sensor and the settings for the alarm contact.
5.6
General
Unit alarm, group has been paused
The valve group has paused irrigation due to an alarm message triggered by the
substrate unit.
Check:
The fluid level of the mixer tank.
The pump (thermal alarm from system pump).
The flow, pressure, EC, pH and water temperature.
Pump alarm, group has been paused
The valve group has paused irrigation due to a pump alarm.
Check:
The pump (thermal alarm from system pump).
The flow and pressure.
Alarm buffer full, oldest alarm message has been removed
The alarm buffer is full. The oldest alarm message has been removed.
Flow rate of valve unknown. Execute flow rate measurement program.
The controller has failed to register the flow rate of the valve.
Run the Flow rate measurement program.
No active valves in group. Group not activated.
The valve group has not been activated, because no valves in the group were
activated.
Aqua CX300
87