The longitude of the greenhouse location.
If the greenhouse is located east of the zero-meridian (Greenwich), then enter the
degree of longitude as a negative number (eastern longitude). If your greenhouse is
located west of Greenwich, then enter the degree of longitude as a positive number
(western longitude). The default value is -4.3 (Pijnacker, the Netherlands).
The latitude of the greenhouse location.
If the greenhouse is located north of the equator, then enter the degree of latitude as
a positive number (northern latitude). If the greenhouse is located south of the
equator, then enter the degree of latitude as a negative number (southern latitude).
The default value is 52.0 (Pijnacker, the Netherlands).
Time zone -12 - 12 hours
The time zone in relation to Greenwich Mean Time.
This time zone is used to calculate at what times sunrise and sunset will
occur.
Synopta
Select whether Synopta is present or not. The Synopta software enables you to
operate and display information from the Aqua CX300 using a PC.
Yes: Is present.
No: Is not present.
Alarm test
Yes: Generate an alarm message for testing purposes. After the alarm message has
been generated, this setting will automatically revert to No.
No: Do not generate an alarm message for testing purposes.
Weather configuration
Outside temperature
Max. temperature change rate
Radiation measurement
Radiation smooth rate
Wind speed measurement
Rain detection
Outside RH measurement
Path: Settings>General>Weather Configuration
Outside temperature measurement
Yes: Activate the outside temperature measurement.
Maximum temperature change rate
The maximum rate at which the temperature may rise or fall per second.
Aqua CX300
49
Summary of Contents for Aqua CX300
Page 1: ...SV 02 03 2020 96010102 User Manual Aqua CX300...
Page 92: ......