Part IV Setting Parameters
BECS-09 Singular-head Computerized Embroidery Machine 51
This is to limit the main shaft speed during jump stitch code.
Start Run Speed: (Options: 120~150)
This parameter is to set the start-up rotation speed of the main shaft at the
start-up.
Start Slow Sti. Num.: (Options: 1~9)
This parameter is to set how many slow start-up stitches are for the startup.
Acceleration: (Options: 1~10)
This parameter is to set the acceleration for the speed to rise after the slow
startup stitches. The larger the parameter value is, the more quickly the
machine speed rise from the startup speed to the maximum speed.
Adjust Speed: (Options: 1~5)
This parameter is to make the real speed nearer to the set speed. It is used
to compensate for the gap between the real speed and the set speed which often
happens with season change.
Adjust Stop Pos.: (Options: 0~ 20)
This parameter is to make the machine stop at the 100 degrees more
accurately. The user can increase the parameter value to stop the main shaft at
a larger angle. Therefore the user can adjust the value between 0 and 20 by
judging whether the shaft exceeds the stop position (100 degrees).
Needles In A Head: (Options: 3~15)