143
Ti-P1 Training
Slide 143
2. Energy Saving
2.3 Energy Save Effectiveness – 1
With the data from SP 8941:Machine Status, and the power
consumption values from the specifications, we can
estimate the amount of energy that is used by the machine.
8941-001: Operating mode time
8941-002: Standby mode time
8941-004: Low power mode
time
8941-005: Off/sleep mode time
This should only be used as a reference value, because the
power consumption specifications are measured in a
controlled environment with a constant power supply.
To get an exact measurement at the customers site, a watt
meter must be used to measure the actual energy
consumed.