123
Ti-P1 Training
Slide 123
IBACC Gradation Correction
Original
Image by
toner
25%
50%
75%
100%
Too light
25%
50%
75%
100%
Too dark
Original
coverage:25%
Before IBACC
After IBACC
25%
50%
75%
100%
Coverage
Original
coverage:75%
25%
75%
31%
Corrected
63%
Corrected
31%
63%
Adjust the
coverage
Before IBACC, the machine’s response is shown by the red curve. IBACC
changes the response so that it is more linear, as shown by the blue line.
However, the machine's response may drift away from linear with time. At
this time, IBACC should be done again.