110
Ti-P1 Training
Slide 110
Fusing Temperature Control
Warming-up Mode
Fusing warm-up begins after the machine power
is switched on.
The fusing lamps heat without roller rotation until
the temperature reaches the “pre-rotation start
temp.”
There is no roller rotation, in order to heat the
lubricant between the heating pipe and the fusing
belt so that the pressure roller rotation will move
the belt.
Then, the fusing motor turns on, until the fusing
temperature reaches the “start-up temperature”
(also called the “reload temperature”).
No additional notes