9 November, 2001
CHECKING ITEMS USING RSS
APPENDIX-5
CC Auto Call
The CC auto call will be automatically generated when “0: Previous Mode” is
selected with SP5-508-4 (default is “1”). There are three types of CC auto calls as
follows.
CC Code
Definition
CC 101
When a paper jam is detected five times consecutively, CC101 is
automatically generated.
CC 201
When a paper jam condition is not reset for 15 minutes, CC201 is
automatically generated.
CC 202
When a cover is left open for 15 minutes, CC202 is automatically
generated.
Alarm Calls
There are four types of Alarm Calls as follows:
Type
Definition
PM
When the PM counter reaches 120,000, a PM Alarm Call is automatically
reported to the Concorde system.
Original Count
An alarm call is generated after the specified total number of originals goes
through the ARDF.
SC
When the SC alarm counter reaches 5, an SC Alarm Call is automatically
generated. The SC alarm counter counts the number of SCs and it
decreases when an SC does not occur for a specified number of copies.
Jam
When Jam alarm counter reaches 10, a Jam Alarm Call is automatically
generated. The Jam Alarm counter counts the number of paper jams and it
decreases when a paper jam does not occur for a specified number of
copies.
1.3.3 READ AND WRITE ITEMS
All data for SP modes and UP modes, except for a few modes.
1.3.4 EXECUTE ITEMS
Item
Item
Memory all clear
Counter reset (all except total counter)
SC reset
Original counter reset
PM counter reset
Copy counter reset
SC/Jam counter reset
Reset counters by each paper tray