SERVICE PROGRAM MODE
10 August, 2001
4-50
7
Mode Number/Name
Function/[Setting]
ROM No./Firmware Version
801
Displays the ROM number and firmware version
numbers.
PM Counter Display
803*
Displays the PM counter since the last PM.
PM Counter Resets
804
Resets the PM counter. To reset, press Execute on the
touch panel.
SC/Jam Counter Reset
807
Resets the SC and jam counters. To reset, press
Execute on the touch panel.
This SP does not reset the jam history counters: SP7-
507, SP7-508.
Resets Counters
808
Resets all counters except SP7-003-***, SP7-006-***
and SP7-007-***. To reset, press Execute on the touch
panel.
Key Operator Code Reset
810
Use to clear the key operator code if the key operator
forgets the code. After clearing the code is reset for
Null and the password entry display does not open. To
clear, press Execute on the touch panel.
Original Count Clear
811
Clears the original total display, displayed with SP7-
002-***. To clear, press Execute on the touch panel.
Print Counter Reset
1
Tray1
2
Tray2
3
Tray3
4
Tray4
5
LCT
816
6
By-pass
Resets the total copy count by paper tray. To reset,
press Execute on the touch panel.
Use these SP modes when replacing the pick-up, feed,
and separation rollers.
Copy Counter Reset Magnification
822
Resets all counters of SP7-301 (Copy Count:
Magnification). To reset, press Execute on the touch
panel.
Total Counter Reset
825
Resets all electronic counters. To reset,
press Execute
on the touch panel.
Usually, this SP mode is done at installation. This SP
mode is effective only once, when the counter has a
negative value.
MF Device Error Count
1
Error Count
Japan only DFU
826
2
Staple Error Count
Japan only DFU
MF Device Error Count Clear
827
Japan only DFU