SERVICE PROGRAM MODE
10 August, 2001
4-40
5
Mode Number/Name
Function/[Setting]
Application Counter Display
1
Printer
914*
2
Copy
Selects whether the total counters for printer mode
and/or copy mode are displayed in user tool mode.
[
0 = No
/ 1 = Yes]
Mechanical Counter Detection
915*
Checks whether the mechanical counter inside the
inner cover is connected or not.
Display:
0: Not detected
1: Detected
2: Unknown
A3/DLT Counter Display
918*
Displays the counter, which counts A3/DLT as double.
0 = No
, 1 = Yes
The A3/DLT counter counts up twice when an A3 or
DLT sheet is fed out.
Fan Control Time
921*
Adjusts the exhaust fan motor control time.
1. After the machine has entered energy saver mode
or stand-by mode, the machine slows the fan
speed after this time runs out.
2. After the machine has entered the auto off mode or
an error condition, the machine stops the fan after
this time runs out.
[30 ~ 120 /
30 s
/ 1 s/step]
Border Erase Area Change
923*
Toggles between two settings that affect the
appearance of the pages for border removal and
printed facing pages: (1) Using the original area as the
allotted area, or (2) Using only the copy paper as the
allotted area.
[
0 = Original base
, 1 = Copy base]
0: Original area used as base
1: Copy used as the base
Feed Clutch Start Timing Adjustment
958*
Adjusts the clutch timing to optimize the intervals
between fed sheets to reduce jams in the feed unit.
[35 ~ 57.5 /
42.5
/ 2.5mm]
Debug Serial Output
970*
DFU
[
0 = No
, 1 = Yes]
Test Suite Setting
1*
GWIPC Logging
DFU
[
0 = Off
, 1 = On]
3*
Key Monitor
DFU
[
0 = Off
, 1 = On]
4
Key Monitor - Record
DFU
[
0 = Off
, 1 = On]
5
Key Monitor - Play
DFU
[
0 = Off
, 1 = On]
972
6*
Key Monitor – Play
Check
DFU
[
0 = Off
, 1 = On]