21 December, 2001
BIT SWITCHES
3-51
Service
Tables
G3-2 Switch 08
- Not used (do not change the settings)
G3-2 Switch 09
- Not used (do not change the settings)
G3-2 Switch 0A
SP No. 1-106-011
No
FUNCTION
COMMENTS
0
1
Maximum allowable carrier
drop during image data
reception
Bit 1
Bit 0
Value (ms)
0
0
200
0
1
400
1
0
800
1
1
Not used
These bits set the acceptable modem carrier drop
time.
Try using a longer setting if error code 0-22 is
frequent.
2-3
Not used
Do not change the settings.
4
Maximum allowable frame
interval during image data
reception.
0:
5 s
1:
13 s
This bit set the maximum interval between EOL
(end-of-line) signals and the maximum interval
between ECM frames from the other end.
Try using a longer setting if error code 0-21 is
frequent.
5
Not used
Do not change the settings.
6
Reconstruction time for the first
line in receive mode
0:
6 s
1:
12 s
When the sending terminal is controlled by a
computer, there may be a delay in receiving page
data after the local machine accepts set-up data and
sends CFR. This is outside the T.30
recommendation. But, if this delay occurs, set this
bit to 1 to give the sending machine more time to
send data.
Refer to error code 0-20.
ITU-T T.30 recommendation: The first line should
come within 5 s of CFR.
7
Not used
Do not change the settings.