SERVICE RAM ADDRESSES
21 December, 2001
3-84
6800E8(H) - User parameter switch 24 (SWUSR_18)
Bits 0 and 1: File retention time (Cross reference: System switch 02 bit 4)
Bit
1
0 Setting
0
0
File retention impossible
0
1
24 hours
1
0
File retention impossible
1
1
72 hours
Bits 2 to 7: Not used
6800E9(H) - User parameter switch 25 (SWUSR_19)
Bits 0 to 3: Not used
Bit 4: RDS operation
0: Not acceptable
1: Acceptable for the limit specified by system switch 03
Note:
This bit is only effective when RDS operation can be selected by the user
(see system switch 02).
Bits 5 to 7: Not used
6800EA(H) to 6800ED(H) - User parameter switch 26 to 29 (SWUSR_1A to 1D)
: Not used
680EE(H) - User parameter switch 30 (SWUSR_1E)
Bits 0 to 6: Not used
Bit7: On hook dialing
0: PSTN, 1: ISDN
Note:
If this bit set to 1, the on hook dialing is available on the ISDN line. But, the
machine cannot use the G3 standard analog line for detecting the ringing
and on hook dialing.
6800F0 to 6800FF(H)
- G4 Parameter Switches
680100 to 68011F(H)
- G4 Internal Switches
680160 to 68016E(H)
- Service station’s fax number (SP3-101)
See 68030C(H) for the type of network used for this number
.
68016F to 68017D(H)
- Own fax PABX extension number
68017E to 68018C(H)
- Own fax number (PSTN)
68018D to 68019B(H)
- Own fax number (ISDN G4)
68019C to 6801AA(H)
- The first subscriber number (ISDN G3)
6801AB to 6801B9(H)
- The second subscriber number (ISDN G3)
6801BA to 6801C8(H)
- The first subscriber number (ISDN G4)
6801C9 to 6801D7(H)
- The second subscriber number (ISDN G4)
6801D8 to 6801EB(H)
- PSTN-1 RTI (Max. 20 characters - ASCII) - See the
following note.
680217 to 680256(H)
- TTI 1 (Max. 64 characters - ASCII) - See the following
note.
680257 to 680296(H)
- TTI 2 (Max. 64 characters - ASCII) - See the following note.
680297 to 6802AA(H)
- PSTN-1 CSI (Max. 20 characters - ASCII)
6802AB to 6802BE(H)
- PSTN-2 CSI (Max.20 characters - ASCII)
6802D3(H)
- Number of PSTN-1 CSI characters (Hex)
6802D4(H)
- Number of PSTN-2 CSI characters (Hex)