SC106 - Low FL Temperature
Definition:
During stand-by, the main PCB detects a high resistance (> 5.6k: 10°C) of
the FL thermistor for more than 15 minutes.
NOTE: 1. No detection in copy mode.
2. 24 V (VP) and 38 V (VFL) will be cut by the relays on the dc
drive PCB in this SC condition.
Points to check:
•
Exposure lamp heater
•
FL thermistor
•
FL temperature fuse
•
DC drive PCB
•
Main PCB (CN102-B20)
SC108 - V
L
Correction Error
Definition:
Target V
L
value cannot be achieved within the exposure lamp output control
range during the process control data initialization.
NOTE: After resetting the system error condition, V
L
correction will be
tried again. Even if the second execution fails, no service call
condition is displayed and the copier uses previous reference
data until its next initialization.
Points to check:
•
Exposure lamp
•
Drum potential sensor
•
Drum
•
Optics dirtiness
•
V
L
sensor pattern
•
Erase lamp